Blancett® QuikSert® Explosion-Proof Turbine Flow Meters
Description
Simple in design and construction, the Blancett® QuikSert® flow meter utilizes modified upstream and downstream flow straighteners for a high degree of flow accuracy. The “between-the-flange” design eliminates the need for mating flanges, requiring less space in the flow line, lowering costs, and providing easy, one-person installation. This flow meter has precision upstream and downstream flow straighteners to ensure a high degree of measurement accuracy.
The QuikSert® explosion-proof in-line turbine flow meter for hazardous locations with no magnetic pick up was developed for liquid applications where accuracy and dependability are needed. The In-Line Turbine flow meter provides the high accuracy and rigorous design of the standard Blancett® turbine, but in a wafer-style mounting configuration. The stainless steel body incorporates a helical turbine with tungsten carbide shaft and bearing. It provides an efficient, long service life and a cost-effective solution for your measurement requirements. Simple in design and construction, it uses modified upstream and downstream flow straighteners for a high degree of flow accuracy. Its between-the-flange design eliminates the need for mating flanges, requiring less space in the flow line, lowering costs for easy, one-man installation.
Features
Explosion proof version with no magnetic pickup
Unique between-the-flange design, which eliminates the need for mating flanges and saves both installation time and cost.
Features a 316 stainless steel body, which incorporates a helical turbine with tungsten carbide shaft and bearing to provide a long service life.
Maintains a +1% accuracy rate, even in aggressive environments where accuracy and dependability are needed.
Built with a between-the-flange design and wafer-style mounting configuration for simple installation in limited space requirements.
Accurate and repeatable flow measurement from 0.6 to 3 gpm(20 to 100 bpd) to 500 to 5000 gpm (17,000 to 171,000 bpd).
Unique between-the-flange design eliminates need for mating flanges
Superior materials of construction for high performance in aggressive environments
Wafer-style mounting configurations for limited space requirements
Modified flow straighteners for enhanced fluid dynamics
Specifications
316/316L stainless steel body
CD4MCU stainless steel
Tungsten carbide bearings and rotor shaft
316L Stainless steel rotor support
No magnetic pickup
-150° to 350° F (-101° to 177°C) operating temperature
Wafer style ASME/ANSI B16.5-1996 end connections
±1% accuracy
±0.1% repeatability
Water NIST traceable calibration
Conformance: NACE MR0175/ISO 15156
Part NumberStrainer MeshFlow RangesK-Factor Pulse/GalMax. Pressure Drop
B131C-038
60
0.6-3 GPM
18,000
3.75 PSI
B131C-050
60
0.75-7.5 GPM
13,000
6.5 PSI
B131C-075
60
2-15 GPM
3,3000
18 PSI
B131C-088
60
3-30 GPM
3,100
20 PSI
B131C-100
60
5-50 GPM
870
20 PSI
B132C-050
60
0.75 to 7.5 GPM
13,000
12 PSI
B132C-075
60
2.0 to 15 GPM
3,300
18 PSI
B132C-088
60
3 to 30 GPM
3100
20 PSI
B132C-100
40
5-50 GPM
870
20 PSI
B132C-150
20
15-180 GPM
20
9 PSI
B132C-200
20
40 to 400 GPM
52
9 PSI
B132C-250
10
40-400 GPM
52
10 PSI
B133C-300
10
60-600 GPM
57
10 PSI
B133C-380
10
80- 800 GPM
57
10 PSI
B134C-400
10
100-1200 GPM
29
10 PSI
B136C-600
4
200- 2500 GPM
7
10 PSI
B138C-800
4
350-3500 GPM
3
10 PSI
B139-900
4
500-5000 GPM
1.6
10 PSI